| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | SHUOBODA |
| Model Number : | RCZ-Y8A |
| Certification : | ISO/CE |
| Price : | Negotiable |
| Payment Terms : | ,L/C,T/T |
| Supply Ability : | 500 sets/month |
| Delivery Time : | 5~8 working days |
The RCZ-Y8A automatic dissolution sampling system is composed of shuoboda DP-RC-8A intelligent drug dissolution tester and DP-RC-Y8A automatic sampling system. It is upgraded and developed in strict compliance with the current "Chinese Pharmacopoeia" and "Guiding Principles for Mechanical Validation of Drug Dissolution Instruments" An 8-channel high-performance drug dissolution testing device that fully complies with data integrity specifications.
Product Features:
>It has built-in three-level user rights management, audit tracking, and test record management. Through the device interface, test reports can be printed or output via USB.
>Commonly used sample information management for easy retrieval and use.
>Commonly used test plans are managed for easy retrieval and use.
>High-precision real-time constant temperature control, independent temperature measurement for each dissolution vessel, dual over-temperature protection and temperature calibration functions.
>There is scheduled heating inside, and the user can set the system to start heating at a specified time.
>Manual and automatic synchronized dosing functions.
>Manual and automatic sampling dual modes.
>Split agitator design, quick replacement.
>The dissolution vessel and stirrer are automatically centered.
>Sealed anti-evaporation cover design effectively reduces medium evaporation.
>Use a more convenient water circulation pipeline design and professional medical grade quick connectors.
>Use high-precision syringe pump.
>When sampling, the sampling needle enters the dissolution vessel to avoid disturbing the flow.
>The sample is replenished isothermally.
>Secondary filtering can be performed.
>The system automatically rinses the pipeline before sampling and automatically empties the pipeline after sampling.
>IQ/OQ certification documents are provided free of charge.
Specifications:
Product model | RCZ-Y8A | |
Dissolution apparatus parameters | Dissolution channel | 8 channels |
Stirring paddle swing range | ≤0.5mm | |
Basket swing range | ≤1.0mm | |
Deviation of rotary rod and dissolution vessel axis | ≤1.0mm | |
Speed setting range | 10~300RPM | |
Steady speed error | ≤±1% | |
Temperature range | Room temperature~45.0°C | |
Temperature resolution | 0.1°C | |
Temperature control accuracy | ≤±0.3°C | |
Sampler parameters | sampling channel | 8 channels |
Sampling times | ≤15 times | |
Sampling timing time | ≤999 hours, 59 minutes and 59 seconds | |
Sampling volume, replenishment volume | ≤10ml | |
Sampling accuracy | ≤±1%, sampling volume 10ml, average value of each channel | |
Sampling interval | 1 minute for the first time, 2~5 minutes thereafter (depending on the sampling volume) | |
sample collection bottle | 120 | |
Power | AC220V±10% 50HZ | |
Products Gallery
>>

>>

>>

|