TLD Thermoluminescence Dosimeter Reader
Product introduction
DA-2000D type thermoluminescence dose reader can measure the
thermoluminescence detector (hereinafter referred to as the
detector) after being irradiated by X, γ, β, neutron and other
rays, and give the readout value and dose value. , with functions
such as automatic calibration, background subtraction, heating
parameter setting and printing. The thermoluminescent dose reader
can be connected to a computer, and data management and printing
can be performed through the application software of the
thermoluminescent dose reader. Conforms to the national standard of
the People's Republic of China GB 10264-88 "Thermoluminescence
dosimetry system for personal and environmental monitoring".
DA-2000D thermoluminescent dose reader adopts 7-inch color touch
screen, which has clear display and easy operation.
Features
• 7-inch touch screen, full Chinese color display, built-in printer, easy for users to operate, operate and maintain;
• The high voltage part has three modes: automatic, locked, fixed;
• The heating plate can be replaced, which is convenient for the measurement of thermoluminescence detectors of different shapes and specifications;
• The database supports a variety of query functions such as unit name, personal name, gender, dose box barcode, date of measurement, tested personnel, untested personnel, etc.;
• Power-on automatic drying function, suitable for instruments with humid environment and low frequency of use;
• An attenuation filter can be placed to expand the dose measurement range.
• With PC software, barcode scanner interface; stand-alone storage of 1000 pieces of measurement data.
• Support scanning code entry, form export, and personal database filing.
Technical parameters
Light measurement system | |
Dose test range | LiF: Mg, Ti: 10-5Gy ~ 1Gy LiF: Mg, Cu, P: 10-7Gy ~ 10Gy LiF: Mg, Ti-M: 0~100Gy |
Measuring items Heating | X, gamma, beta, neutron |
System stability | ≤0.2% |
Measurement and reading time | 40s (can be customized) |
Coefficient of variation of sensitivity repeatability | ≤0.1%±0.05%/℃ |
Drawer light leakage | ≤0.1% of internal light source |
Background value | ≤300 |
High voltage | 0~1500V |
Power supply | AC 220V±10%, 50Hz |
Heating system | |
Heating temp. range | Room temperature~400℃ |
Temperature repeatability | ≤1% |
Heating temperature deviation | ≤±2℃ |
Heating time | 0~500s |
Heating time repeatability | ≤0.1% |
Heating rate | 1~40℃·s-1 |
Use conditions | |
Working environment | Indoor |
Working temperature | 10~40℃ |
|